Negative
Sharp linear
Varies
Change in section or area restricted by features of the die or core
Visual inspection
Release of internal or externally applied stress
Area | Possible Cause | Potential Correction |
---|---|---|
Equipment | Out of calibration |
See Best Practices Section |
Equipment | Cold platen |
Increase platen temperature. |
Equipment | Excessive cycle time |
Decrease cycle time |
Equipment | Hot wax |
Reduce wax injection temperature |
Equipment | Clamp opening too fast |
Reduce clamp opening speed |
Pattern Die | Cold die |
Increase die temperature |
Pattern Die | Burr in die |
Have too maker remove burrs |
Pattern Die | Die mismatch |
Check guide pins for wear or improper alignment. |
Wax | Filler separation |
Check for proper agitation of wax. Discard suspect wax. Check temperature during conditioning process. |
Other | Opening Die too fast |
Reduce speed of die opening |
Other | Improper removal of pattern |
Proper training of personnel for pattern removal technique and tools. Note: Use a gentle air assist by blowing along the parting line loosen from die. Always make sure the pattern is being withdrawn evenly. Apply even pressure to avoid bending pattern. |